Indore is Madhya Pradesh's commercial capital, and its industrial strength lies in Pithampur, often called the Detroit of central India. Automotive, pharma and engineering units in Pithampur, Sanwer Road and Dewas drive regional demand.
VA Electricals designs and manufactures single-phase, three-phase and multi-tap control transformers at its works in Bhosari, Pune. Every unit is built to your voltages and rating and tested in-house, then delivered by road to customers in Pithampur Sector 1, Pithampur Sector 2, Pithampur Sector 3 and across Indore.
Built for 230 V single-phase / 415 V three-phase, 50 Hz, with control secondaries such as 24 V, 110 V or 230 V, or any voltage your panel needs.
A control transformer steps the incoming supply down to a stable control voltage for contactors, relays, timers, solenoid valves, PLC I/O and indicator circuits, while electrically isolating the control circuit from the power circuit. It is designed to hold its secondary voltage during the high inrush current drawn when contactor coils and solenoids pick up.
For panel builders in Indore, a correctly sized control transformer prevents nuisance drop-outs of contactors and relays when several coils energise together, and keeps the control circuit isolated from the power circuit.
For control panels, MCC panels, relay and contactor circuits, solenoid valves and machine control circuits.
View product detailsIsolated power for CNC machines, robotic controllers and process machinery, with or without enclosure.
View product detailsSeveral primary and secondary voltages in one unit, for OEMs who ship machines to different supply standards.
View product detailsPithampur hosts commercial-vehicle and tractor plants and their component suppliers.
Typical use: Control circuits on assembly, welding and test-line equipment.
Pharma SEZ units in Pithampur run formulation lines with clean-room HVAC.
Typical use: Stable, isolated control voltage for panels and machinery.
Soya, snack and food-processing plants run extraction and packaging lines.
Typical use: Stable, isolated control voltage for panels and machinery.
Panel builders on Sanwer Road and in Dewas supply industry across central India.
Typical use: Control voltage for contactor, relay and PLC circuits in MCC and PCC panels.
Textile and yarn units in Dewas and Ujjain run spinning machinery.
Typical use: Stable, isolated control voltage for panels and machinery.
Large solar parks across Madhya Pradesh need power-conversion equipment.
Typical use: Stable, isolated control voltage for panels and machinery.
Plants in Indore see summer heat in panel rooms, monsoon humidity and supply fluctuations. Share your duty cycle and ambient conditions, and we design the rating, insulation and construction to suit.
| Phase | Single phase / Three phase |
|---|---|
| Rating | Up to 200 kVA (three-phase); VA ratings for control circuits |
| Primary voltage | 230 V / 415 V or multi-tap, as specified |
| Secondary voltage | 24 V, 48 V, 110 V, 230 V or as specified |
| Frequency | 50 Hz (Indian grid standard) |
| Winding | Double-wound isolation (auto-transformer on request) |
| Construction | Open frame or enclosed; mounting as per application |
| Compliance | CE marked under LVD 2014/35/EU (transformers up to 200 kVA); ISO 9001:2015 production |
| Routine tests | Ratio, no-load, insulation resistance, HV breakdown, winding resistance |
Orders for Indore are dispatched by road from our works in Bhosari, Pune, about 590 km away. Every consignment is packed to protect windings and terminals in transit. Consignments travel by road transport with dispatch details shared in advance, so your project or production schedule stays on track.
Send your requirement



Of transformer design and manufacturing experience behind every unit.
ISO 9001:2015 quality system and CE conformity under the Low Voltage Directive.
Voltages, ratings, terminals and mounting made to match your design.
Production planned around your project schedule and delivery dates.
Yes. VA Electricals manufactures single-phase, three-phase and multi-tap control transformers at its works in Pune, India and supplies customers across Indore, including Pithampur Sector 1, Pithampur Sector 2, Pithampur Sector 3, Sanwer Road, Dewas.
Yes. Units are built for the 230 V single-phase / 415 V three-phase, 50 Hz supply used in Indore, with control secondaries such as 24 V, 110 V or 230 V, or any voltage your panel needs.
Control transformers are made in single-phase and three-phase designs, with three-phase units up to 200 kVA and VA ratings to suit control circuits. Multi-tap versions combine several primary and secondary voltages in one unit.
VA Electricals operates an ISO 9001:2015 certified quality management system and holds MSME ZED Bronze certification. Its products carry CE conformity under the Low Voltage Directive 2014/35/EU, covering transformers up to 200 kVA.
Dispatched by road from our Pune works, about 590 km away, packed to protect windings and terminals in transit.
Yes. Tell us the ambient temperature, duty cycle and supply conditions at your plant, and we design the rating, insulation and construction to suit.
Share your voltages, rating and quantity. Our engineers will send a technical offer for supply to Pithampur Sector 1, Pithampur Sector 2, Pithampur Sector 3 or anywhere in Indore.