Current Transformers manufactured by VA Electricals for Navi Mumbai
Supplied across Navi Mumbai
MANUFACTURER · SUPPLIER · NAVI MUMBAI

Current Transformers for Navi Mumbai, Maharashtra

Navi Mumbai's Trans-Thane Creek (TTC) MIDC, stretching from Turbhe and Mahape to Rabale and Pawane, is a dense cluster of electronics, engineering and chemical units. Taloja MIDC and the JNPT port corridor add heavy industry, warehousing and export-oriented plants.

VA Electricals designs and manufactures toroidal current transformers at its works in Bhosari, Pune. Every unit is built to your voltages and rating and tested in-house, then delivered by road to customers in TTC MIDC Turbhe, Mahape, Rabale and across Navi Mumbai.

Matched to the Navi Mumbai supply

Rated for 230 V single-phase / 415 V three-phase, 50 Hz systems, with ratios selected to suit your meters, relays and protection scheme.

ISO 9001:2015 CE – LVD 2014/35/EU MSME ZED Bronze
PRODUCT OVERVIEW

What Does a Current Transformer Do?

A current transformer (CT) produces a secondary current proportional to the current in a primary conductor, so meters, relays and controllers can measure high currents safely. VA Electricals makes toroidal CTs, whose ring shape uses space and material efficiently to give compact, accurate and cost-effective units.

In Navi Mumbai, our CTs feed energy meters, protection relays and monitoring systems in LT panels, inverters and power electronics.

Up to 5000 APrimary current, toroidal design
Built to specificationVoltages, ratings and mounting to your drawing
100% routine testedRatio, insulation resistance, HV breakdown, winding resistance
Road deliveryAbout 120 km from our Pune works
OUR RANGE

Current Transformers We Supply in Navi Mumbai

Toroidal Current Transformers

Compact, efficient ring-type CTs for metering and current sensing.

View product details

Tape Wound Current Transformers

Tape-wound cores for accurate, repeatable measurement.

Custom Ratio CTs

Ratios, burden and window size made to your panel or product design.

APPLICATIONS IN NAVI MUMBAI

Where Our Current Transformers Are Used in Navi Mumbai

Electronics & Power Equipment

TTC MIDC units in Mahape and Rabale build electronic, UPS and power-conversion equipment.

Typical use: Toroidal CTs for current sensing inside electronic equipment.

Pharma & Chemicals

Taloja MIDC is a major chemical and pharmaceutical zone with continuous-process plants.

Typical use: Current measurement for metering, protection and energy monitoring.

Data Centres & IT

Data centres in Mahape, Airoli and Rabale need reliable UPS and power-quality equipment.

Typical use: Energy monitoring on UPS and distribution feeds.

Control Panel Builders

Panel builders in Pawane and Turbhe supply automation and distribution panels.

Typical use: Metering and protection inputs for LT panels and energy meters.

Steel, Foundry & Metals

Engineering and fabrication workshops in Taloja and Panvel run welding and heavy machinery.

Typical use: Current measurement for metering, protection and energy monitoring.

Plastics & Packaging

Plastic processing and packaging units run moulding and extrusion machines on VFDs.

Typical use: Current measurement for metering, protection and energy monitoring.

ENGINEERED FOR INDIAN PLANTS

Built for Indian Plant Conditions

Plants in Navi Mumbai see summer heat in panel rooms, monsoon humidity and supply fluctuations. Share your duty cycle and ambient conditions, and we design the rating, insulation and construction to suit.

  • Compact toroidal construction
  • Ratios matched to meters and relays
  • Accurate, repeatable output
  • Window size to suit your busbar or cable
TECHNICAL DATA

Current Transformer Specifications

TypeToroidal / tape wound
Primary currentUp to 5000 A
Secondary currentAs per meter or relay requirement
ApplicationMetering, protection, current sensing
System230 V single-phase / 415 V three-phase, 50 Hz installations
MountingCable or busbar through-window, as specified
ComplianceCE marked under LVD 2014/35/EU (CTs up to 5000 A); ISO 9001:2015 production
Routine testsRatio, insulation resistance, HV breakdown, winding resistance
DELIVERY

Delivering Current Transformers to Navi Mumbai

Orders for Navi Mumbai are dispatched by road from our works in Bhosari, Pune, about 120 km away. Every consignment is packed to protect windings and terminals in transit. Being this close, deliveries are quick and our engineers are easy to reach for technical discussions or site visits.

Send your requirement
AREAS WE SERVE

Industrial Areas We Serve in Navi Mumbai

  • TTC MIDC Turbhe
  • Mahape
  • Rabale
  • Pawane
  • Ghansoli
  • Taloja MIDC
  • Vashi
  • Airoli
  • Belapur
  • Panvel
PRODUCT GALLERY

Current Transformers Built at Our Pune Works

Current Transformer for Navi Mumbai – VA Electricals
Current Transformer for Navi Mumbai – VA Electricals
Current Transformer for Navi Mumbai – VA Electricals
Current Transformer for Navi Mumbai – VA Electricals
WHY VA ELECTRICALS

Why Buyers in Navi Mumbai Choose Us

12+ Years

Of transformer design and manufacturing experience behind every unit.

Certified Quality

ISO 9001:2015 quality system and CE conformity under the Low Voltage Directive.

Built to Drawing

Voltages, ratings, terminals and mounting made to match your design.

On-Time Dispatch

Production planned around your project schedule and delivery dates.

FAQ

Current Transformers in Navi Mumbai – Frequently Asked Questions

Do you supply current transformers in Navi Mumbai?

Yes. VA Electricals manufactures toroidal current transformers at its works in Pune, India and supplies customers across Navi Mumbai, including TTC MIDC Turbhe, Mahape, Rabale, Pawane, Ghansoli.

Are your current transformers suitable for the 415 V, 50 Hz supply in Navi Mumbai?

Yes. Units are built for the 230 V single-phase / 415 V three-phase, 50 Hz supply used in Navi Mumbai, with ratios selected to suit your meters, relays and protection scheme.

What current ratings of CTs are available?

Our CE conformity covers current transformers up to 5000 A. Ratios, burden and window dimensions are made to suit your meters, relays and panel layout.

What certifications do VA Electricals current transformers carry?

VA Electricals operates an ISO 9001:2015 certified quality management system and holds MSME ZED Bronze certification. Its products carry CE conformity under the Low Voltage Directive 2014/35/EU, covering current transformers up to 5000 A.

How are current transformers delivered to Navi Mumbai?

Dispatched by road from our Pune works, about 120 km away, packed to protect windings and terminals in transit.

Can you design current transformers for site conditions in Navi Mumbai?

Yes. Tell us the ambient temperature, duty cycle and supply conditions at your plant, and we design the rating, insulation and construction to suit.

Need Current Transformers Delivered to Navi Mumbai?

Share your voltages, rating and quantity. Our engineers will send a technical offer for supply to TTC MIDC Turbhe, Mahape, Rabale or anywhere in Navi Mumbai.