Thane district is one of Maharashtra's oldest engineering belts. Wagle Estate, Ambernath, Dombivli and Badlapur MIDCs host machine builders, chemical plants and panel manufacturers, while Bhiwandi has grown into a major warehousing and textile cluster.
VA Electricals designs and manufactures buck boost transformers at its works in Bhosari, Pune. Every unit is built to your voltages and rating and tested in-house, then delivered by road to customers in Wagle Estate, Thane-Belapur Road, Kolshet and across Thane.
Built for 230 V single-phase / 415 V three-phase, 50 Hz, with the buck or boost amount chosen to bring your supply to the equipment's rated voltage.
A buck boost transformer raises (boosts) or lowers (bucks) the supply voltage by a small amount so equipment receives the voltage it is designed for. Because it only handles the correction voltage, it is far smaller and more economical than a full isolation transformer for the same load.
For sites in Thane where the supply sits a little above or below what equipment is rated for, a buck boost transformer corrects the voltage economically, without a full-size transformer.
Lowers a high supply voltage to protect equipment rated for a lower voltage.
View product detailsRaises a low or sagging supply so motors and compressors run at rated voltage.
Designed around your measured supply range and load.
Panel builders along Wagle Estate and the Thane-Belapur Road supply control and distribution panels to industry across western India.
Typical use: Bucking or boosting supply voltage by a small amount to match equipment.
Dombivli and Ambernath MIDCs host many chemical, dye-intermediate and pharma units with process-control panels.
Typical use: Bucking or boosting supply voltage by a small amount to match equipment.
Machine builders in Ambernath, Badlapur and Kalyan make special-purpose, packaging and process machinery.
Typical use: Correcting supply voltage for imported machines rated for a different voltage.
Bhiwandi's powerloom cluster runs thousands of looms that need stable supply and drive protection.
Typical use: Bucking or boosting supply voltage by a small amount to match equipment.
Municipal and industrial water and effluent treatment plants run large pump and blower drives.
Typical use: Bucking or boosting supply voltage by a small amount to match equipment.
Food processing and packaging units in the Thane belt rely on conveyors, fillers and sealing machines.
Typical use: Keeping refrigeration and process motors at rated voltage.
Plants in Thane see summer heat in panel rooms, monsoon humidity and supply fluctuations. Share your duty cycle and ambient conditions, and we design the rating, insulation and construction to suit.
| Function | Buck (step-down) or boost (step-up) voltage correction |
|---|---|
| Rating | As per load and correction required |
| Supply | 230 V single-phase / 415 V three-phase, 50 Hz systems |
| Correction | Set to bring supply to equipment's rated voltage |
| Frequency | 50 Hz (Indian grid standard) |
| Construction | Open frame or enclosed |
| Compliance | CE marked under LVD 2014/35/EU (transformers up to 200 kVA); ISO 9001:2015 production |
| Routine tests | Ratio, no-load, insulation resistance, HV breakdown, winding resistance |
Orders for Thane are dispatched by road from our works in Bhosari, Pune, about 150 km away. Every consignment is packed to protect windings and terminals in transit. Being this close, deliveries are quick and our engineers are easy to reach for technical discussions or site visits.
Send your requirement


Of transformer design and manufacturing experience behind every unit.
ISO 9001:2015 quality system and CE conformity under the Low Voltage Directive.
Voltages, ratings, terminals and mounting made to match your design.
Production planned around your project schedule and delivery dates.
Yes. VA Electricals manufactures buck boost transformers at its works in Pune, India and supplies customers across Thane, including Wagle Estate, Thane-Belapur Road, Kolshet, Bhiwandi, Ambernath MIDC.
Yes. Units are built for the 230 V single-phase / 415 V three-phase, 50 Hz supply used in Thane, with the buck or boost amount chosen to bring your supply to the equipment's rated voltage.
When the supply only needs a small voltage correction and isolation is not required. A buck boost unit handles only the correction voltage, so it is smaller, lighter and lower in cost for the same load.
VA Electricals operates an ISO 9001:2015 certified quality management system and holds MSME ZED Bronze certification. Its products carry CE conformity under the Low Voltage Directive 2014/35/EU, covering transformers up to 200 kVA.
Dispatched by road from our Pune works, about 150 km away, packed to protect windings and terminals in transit.
Yes. Tell us the ambient temperature, duty cycle and supply conditions at your plant, and we design the rating, insulation and construction to suit.
Share your voltages, rating and quantity. Our engineers will send a technical offer for supply to Wagle Estate, Thane-Belapur Road, Kolshet or anywhere in Thane.